System Cable Tube - Image
Cable tube sealing system

System Cable Tube

The System Cable Tube is a particularly easy-to-install cable box made of two pipe half-shells with a click lock and an inner fire protection fabric. Suitable as a fireproof penetration sealing system for electrical cables and lines of all types, electrical installation conduits, and HVAC split lines. Fire-resistant up to max. 120 minutes.

Areas of application

Cable box for the fire sealing of cables and electrical lines in:

  • Plasterboard walls
  • Solid walls
  • Solid floors
  • Timber construction (CLT walls and floors)

Highlights

  • The entire cross-section of the cable tubes can be used
  • Easy retrofitting possible
  • Easy installation, as no additional measures for the aperture edge required
  • Installation around existing lines also possible
  • Also suitable for cable penetration seals in timber construction

Fire resistance class

Max. EI 120 acc. to EN 13501-2

Certificate

ETA-22/0053: Jul 10, 2024

Features

  • Single or group arrangement for sealing existing lines or as a reserve penetration seal for future installations
  • Various diameters and lengths available
  • Suitable for 68 mm socket holes or 100 mm core drill holes
  • Easy to reuse without special tools
  • The plastic half-shells are connected to each other using a click lock

Installation video: System Cable Tube

The system Cable Tube serves to seal penetrations of cables of any type as well as lines of split-line air conditioning systems. Once the Cable Tube is installed in place, it is sealed with the dedicated sealing plug and with fire protection filler FLAMMOTECT-A. System Cable Tube meets the fire resistance requirements of up to class EI 120 as defined in standard EN 13501-2.

System Cable Tube

System information

Technical data

General

Brand name

Flamro Brandschutz-Systeme GmbH, Am Sportplatz 2, 56291 Leiningen

Thickness of building element

Building element

Flexible wall, Rigid wall

Thickness of building element

≥ 100 mm


Building element

CLT wall

Thickness of building element

≥ 100 mm


Building element

Rigid floor

Thickness of building element

≥ 125 mm


Building element

CLT floor

Thickness of building element

≥ 140 mm

Penetration seal thickness

Building element

Flexible wall, Rigid wall, Rigid floor, CLT wal, CLT floor

Penetration seal thickness

≥ 150 mm

Data line

Combustible pipe Ø

Diameter Ø

≤ 32 mm

Single electrical conduit Ø

Single Ø

≤ 63 mm

Cable Ø

≤ 21 mm

Coaxial cables / waveguides Ø

Diameter Ø

≤ 28.5 mm

Cable Ø

Diameter Ø

≤ 80 mm

General

Split HVAC line combinations

yes

speedpipes

Diameter Ø

≤ 7 mm

Quantity

≤ 24


Diameter Ø

≤ 10 mm

Quantity

≤ 7


Diameter Ø

≤ 12 mm

Quantity

≤ 5

Required products

CT Cable Tube - Ø 90 mm length 150 mm

Article number

01279101

CT Cable Tube - Ø 120 mm length 150 mm

Article number

01271151

CT Cable Tube - Ø 90 mm length 200 mm

Article number

01279201

CT Cable Tube - Ø 90 mm length 300 mm

Article number

01279301

CT Cable Tube - Ø 120 mm length 200 mm

Article number

01271201

CT Cable Tube - Ø 60 mm length 150 mm

Article number

01276101

CT Cable Tube - Ø 120 mm length 300 mm

Article number

01271301

GFM - Fire protection mortar, 25 kg bag

Article number

01167000

FLAMMOTECT-A - Filler, 12.5 kg

Article number

01155134

FLAMMOTECT-A - Filler, 310 ml

Article number

01155115

FLAMMOTECT-A - 20 x 600 ml 

Article number

01155153

Mineral wool - 10 kg bag

Article number

01183000

Identification Label, Europe -

Article number

14003

Do you have questions on System Cable Tube and other fire protection applications? Please contact us:

Telephone receiver as telephone icon to call Flamro's hotline.

+49 4105 4090-0

Envelope as e-mail icon to go to the contact form.

Get in touch

How can we help?